Laser Beam Meaurement System

  • Update:Jun 13, 2017
  • View:

The passive cooled sensor of the STCam is constructed without cover glass to avoid interference patterns. For sensor protection a low distortion neutral density filter is integrated.

Product Introduction

The passive cooled sensor of the STCam is constructed without cover glass to avoid interference patterns. For sensor protection a low distortion neutral density filter is integrated. The STCam supports the ultra-fast FireWire IEEE 1394b interface with data transfer rates up to 800 Mbit/s. The plug and play

design facilitates easy and flexible integration and operation.

The portable STCam is designed to be used in a variety of applications in industry, science, research and development, including:

The enhancement of product quality, process reliability and efficiency are just a few of the many benefits of our unique beam profiler cameras. The STCam includes the specifically designed analysis software, STRayCi, which supports Windows XP/Vista operating systems. Its sophisticated software architecture opens up new opportunities in laser beam analysis according to ISO standards.

The concept of the STCam enables easy adaption to standard optical imaging systems, attenuators and opto-mechanical components ensuring highest flexibility. This includes:

ACCESSORIES

Neutral Density Filter:To expand the power range of the STCam several absorptive and metallic-coated neutral density filters are available, which are specified by optical densities ranging from OD 1.0 to OD 4.0.

FireWire Component:We offer different FireWire PCI / PCI Express cards for installation direct into the PC. Standard FireWire cables are suitable for industrial applications and are available in various lengths.

Trigger Device:To synchronize the STCam with pulsed laser systems, our trigger device is perfectly suited. This frequency and delay generator is software controllable and enables the synchronization of up to four beam profilers with different delay times simultaneously.

  CCD-1201 CCD-1301 CCD-2301 CCD-2302
SENSOR DATA
Format 1/2” 1/3” 2/3” 2/3”
Active area 6.5x4.8mm 4.8x3.6mm 9.0x6.7mm 8.5x7.1mm
Number of pixel 1388x1038 (1.4MPixel) 1292x964 (1.2MPixel) 1388x1038 (1.4MPixel) 2452x2056 (5MPixel)
Pixel size 4.65x4.65μm 3.75x3.75μm 6.45x6.45μm 3.45x3.45μm
Spectral response without cover glass 350-1100nm 350-1100nm 350-1100nm 350-1100nm
Laser beam diameter min/max 46.5/4mm 37.5/3mm 64.5μm/5mm 34.5μm/5.5mm
Sensor cooling passive passive passive passive
CAMERA FEATURES
Lens Mount C-Mount C-Mount C-Mount C-Mount
Bit depth (output) 14Bit 14Bit 14Bit 14Bit
Dynamic (signal to noise) 60dB (1:1000) 59dB (1:900) 67dB (1:2200) 54dB (1:500)
Frame rate up to 15Hz up to 30Hz up to 16Hz up to 9Hz
Exposure time 100μs-1s 100μs-1s 100μs-1s 100μs-1s
Interface FireWire (IEEE1394b) FireWire (IEEE1394b) FireWire (IEEE1394b) FireWire (IEEE1394b)
I / O connector 12-Pin Hirose 12-Pin Hirose 12-Pin Hirose 12-Pin Hirose
Mode CW or pulsed CW or pulsed CW or pulsed CW or pulsed
Trigger TTL-signal TTL-signal TTL-signal TTL-signal
Combinable with IR-/UV-Converter Beam expander Attenuator Microscope lens Beam expander Attenuator Beam expander Attenuator Beam expander Attenuator
SPECIFICATIONS
Mechanical dimensions (WxHxL) 60x60x103.8mm 60x60x103.8mm 60x60x103.8mm 60x60x103.8mm
Weight 300g 300g 300g 300g
Electrical requirements DC 8V-36V DC 8V-36V DC 8V-36V DC 8V-36V
Storage temperature* -10°C…+60°C -10°C…+60°C -10°C…+60°C -10°C…+60°C
Operating temperature* +5°C…+45°C +5°C…+45°C +5°C…+45°C +5°C…+45°C
Regulations CE, RoHS CE, RoHS CE, RoHS CE, RoHS

* without condensation

Neutral Density Filter

Our neutral density filters allow broadband attenuation for a spectral range from VIS to NIR. Due to their excellent surface quality the absorptive and reflective filters enable precise beam attenuation for low power applications. The level of attenuation is specified by the optical density. Filters with different optical densities can be combined. A filter adapter is available to mount the filters on the STCam aperture.

Reflective ND filter Absorptive ND filter
NDR-10 / NDR-20 / NDR-30 / NDR-40 NDA-10 / NDA-20 / NDA-30 / NDA-40
Optical density* 1.0 / 2.0 / 3.0 / 4.0 1.0 / 2.0 / 3.0 / 4.0
Spectral range 200nm - 1200nm 400nm - 700nm / 700nm - 1200nm
Material UV-Fused silica (Coating: Metal) Schott glass
Flatness 1λ @ 300nm λ/10 @ 632.8nm
Scratch-Dig 40 - 20 40 - 20
Parallelism: 3arcmin 10arcsec
Optical density tolerance ±5% ±5%
Power (Pmax) < 1W < 1W
Intensity (Imax) 0.75W/cm2 1W/cm2
Diameter ∅=25mm/25.4mm ∅=25mm/25.4mm
Operating temperature < 100°C < 100°C
Filter threads Filter thread / Filter mount Filter thread / Filter mount
Filter adapter C-Mount thread / Filter thread C-Mount thread / Filter thread

CO2 Laser Beam Profiler

The high performance STCL system is based on industry’s unique imaging technique. It is designed for monitoring high-power CO2 lasers in best performance. Thanks to its high resolution and its incomparable real-time capabilities, this highly efficient beam profiler is optimized for laser beam analysis of continuous wave (CW) and pulsed laser systems. The STCL system ensures beam profiling:

The STCL supports the ultra-fast FireWire IEEE 1394a/b interface with data transfer rates up to 800 Mbit/s. The plug and play design facilitates easy and flexible integration and operation.

The compact and portable STCL is designed to be used in a variety of applications in industry, science, research and development, including:

The enhancement of product quality, process reliability and efficiency are just a few of the many benefits of our unique beam profiling system.

The STCL system includes the specifically designed analysis software, STRayCi, which supports Windows XP/Vista operating systems. Its sophisticated software architecture opens up new opportunities in laser beam analysis according to ISO standards.

ACCESSORIES:

Technical Specifications:

  STCL200 STCL500 STCL500
IMAGE CONVERTER
Spectral sensitivity: 8μm - 12μm 8μm - 12μm 8μm - 12μm
Clear aperture: 20mm 30mm 30mm
Laser beam diameter (1/e2): 1mm - 10mm 2mm - 15mm 2mm - 15mm
Intensity range* : 20W/cm2 - 2.000W/cm2 20W/cm2 - 2.000W/cm2 20W/cm2 - 2.000W/cm2
Input power (max): 200W (250W, 30s) 500W (550W, 30s) 500W (550W, 30s)
With attenuation unit 0°: up to 2kW up to 2kW up to 2kW
With attenuation unit 90°: up to 2.5kW up to 3kW up to 3kW
Effective pixel size: x=39μm / y=36μm x=55μm / y=51μm x=30μm / y=29μm
Effective pixel size with 2x binning: x=78μm / y=73μm x=110μ m / y=102μ m x=60m / y=58μm
CAMERA FEATURES*
Sensor: CCD CCD CCD
Resolution (with 2x binning): 752 x 580pixel (367 x 288pixel) 752 x 580pixel (367 x 288pixel) 1384 x 1038pixel (688 x 518pixel)
Frame rate (with 2x binning): up to 25Hz (up to 50Hz) up to 25Hz (up to 50Hz) up to 15Hz (up to 25Hz)
Interface: FireWire (IEEE1394a) FireWire (IEEE1394a) FireWire (IEEE1394b)
Mode: CW or pulsed CW or pulsed CW or pulsed
SPECIFICATIONS      
Mechanical dimensions (WxHxL): 298x141x76mm 340x165x92mm 340x165x92mm
Weight: 2.6kg 3.3kg 3.4kg
Electrical requirements: AC120V/240V; 48 - 63Hz; 320W AC120V/240V; 48 - 63Hz; 570W AC120V/240V; 48 - 63Hz; 570W
Storage temperature** : 0°C…+60°C 0°C…+60°C 0°C…+60°C
Operating temperature** : +5°C…+35°C +5°C…+35°C +5°C…+35°C
Humidity: 20%...80% 20%...80% 20%...80%
Regulations: CE, RoHs CE, RoHs CE, RoHs

Laser Beam Profiling Software STRayCi

Our sophisticated beam profilers are available with the specifically designed analysis software, STRayCi, which supports Windows XP/Vista operating systems. It is available as 32 Bit / 64 Bit version and can control up to eight beam profiler cameras on a single computer.

Due to its clearly designed menu structure, STRayCi shows self-explanatory functions, which help the user to access quickly standard settings. Incomparable visualization modes, extensive analytical capabilities as well as new developed correction algorithms ensure the highest accuracy in laser beam analysis.

A wide range of beam width techniques e.g. 2nd Moment, Knife Edge, Moving Slit, Plateau, Gauss-Fit can be applied to determine quick and reliable standard beam parameters. The unique measurement tool enables the continuous monitoring of beam parameters, beam position and power density distribution. Helpful features like AOI Tracking, AOI Optimization, Zoom Functions, Look-Up Tables, etc.

The extraordinary graphical and analytical tool of STRayCi can be used for live data (LiveMode) and stored data (SaveMode) simultaneously, while each mode has its own inpidual functions. This makes STRayCi the most advanced analysis software on the market.

STRayCi is equipped with flexible data and image output capabilities. This permits the user to store data and images in the format that is compatible with their needs.

A clearly arranged and printable protocol view displays the chosen measurement parameters as well as the most important laser beam analysis results.

STRayCi is compatible with guidelines of the international standard organization for laser beam measurements:

STRayCi works only with a USB software protection lock. It is a hardware based security solutions to protect and encrypt the software against piracy.

MINIMUM SYSTEM REQUIREMENTS:

STRayCi Special Features

CAMERA CONTROL

ANALYSIS FUNCTIONS

CALIBRATION AND CORRECTION TOOL

OTHER FEATURES

FLEXIBLE OUTPUT

Share: